Connecting the Air Hoses
Using the two flexible hoses provided, connect the inlets and outlets of the
drying hopper to the dryer. Check to make sure the dryer is located as close as
possible to the hopper to reduce heat loss. (10 ft {3.05 m} of hose supplied)
If you have ordered an insulated hose, it should be installed between the dryer
outlet and the hopper inlet.
1 Attach one hose from the
return air inlet of the dryer to
the return air outlet from the
top of the hopper.
2 Attach one hose from the
delivery air outlet of the dryer
to the delivery air inlet of the
hopper.
3 Secure hoses with clamps.
The hose clamp should be secured at
least 1/4 inch {6.4 mm} from the end of
the inlet or outlet tube.
3-10 l Ins ta ll ation
NOTE: Do not allow the
flexible hoses to kink or
crimp.
✐
Return
Air Inlet
Delivery
Air Outlet
Connecting the Dryer to the Hopper
The W 15 - 100 dryers have 2 1/2 inch inlet and outlet hose connections.
NOTE: If your dryer hose connection and your hopper hose connection are not the same
size, you will need a hose adapter. Contact Conair Parts 1 800-458-1960.
Hose adapters are available
from Conair.
Contact Conair Parts
(800) 458 1960
From outside of the
United States, call:
(814) 437 6861
✐