6-28 l Tr ou bl es ho ot in g
Checking or Replacing Temperature
Sensors
The Carousel Plus W Series Dryer uses RTD sensors to monitor the temperatures
of the drying air, the return air, the regeneration outlet, the regeneration inlet
process protection and setback at the outlet of the hopper.
To check or replace RTD sensors:
1 Disconnect and lockout the main power supply.
2 Remove dryer cover, as necessary.
3 Locate the RTD sensors.
4 Check the sensor positions and conditions. Temperature readings will be
incorrect, if the sensors are touching the wall of an air hose or pipe or if the
sensor or wiring is damaged. The tip of the sensor should be centered within the
air hose or pipe. Sensor wires should be attached to the appropriate connection
points on the dryers electrical enclosure or microprocessor board.
5 To check with ohm meter, measure the resistance across the RTDs. The
resistance should be approximately 110 ohm at room temperature.
6 Replace the sensor, if necessary.
IMPORTANT
: Always refer
to the wiring diagrams
that came with your
dryer to locate specific
electrical components.
Illustrations in the User
Guide are intended to be
representative only.
Location of
the Process
RTD at the
Hopper inlet.