IDC 255 Progate Drive Thru Service Manual
Publication Number: 621057419SER - 10 - © 2006-2013, IMI Cornelius Inc.
The relationship is expressed below.
Agitation Time (A
T
) = Dispense Time (D
T
) x Agitation Ratio
2
(R
A
)
The agitation time equals the dispense time mu
ltiplied by the agitation ratio. The user is given the flexibility to
change the agitation ratio thereby altering the agitation time in order to ensure that the ice chute is always filled with
ice for all ice types.
Figure 5.
Programming (Changing) the Agitation Time
1. Simultaneously press and hold for 3 seconds, the
button and also both direction arrow buttons
to enter the programming mode.
2. The LED meter turns ON once the programming mode is entere
d. Visual feedback of ratio/agitation time is
obtained from the visual programming LED
. The LED meter shows the existing agitation
ratio enabling the user to vary the agitation time using the directional arrow buttons. Left
to decrease
and right direction arrow button to increase.
3. To exit, repeat Step 1.
170 16 2720
190 16 3
040
210 16 3360
230 16 3680
Dispense Time (mS) Agitation Ratio Agitation Time (mS)
50 28 1400
70 28 1960
90 28 2520
110 28 3080
130 28 3640
150 28 4200
170 28 4760
190 28 5320
210 28 5880
230 28 6440
Dispense Time (mS) Agitation Ratio Agitation Time (mS)