IDC 255 Progate Drive Thru Service Manual
Publication Number: 621057419SER - 32 - © 2006-2013, IMI Cornelius Inc.
NO CARBONATED WATER
NO CARBONATED WATER
Does the
carbonator pump start
when the unit is
turned on
Check the carbonator pump
connection to the E-Board in the E-
Box.
No
Is the
incoming water
restricted
Yes
Restore the recommended
water ow
Yes
Is there
power connection to
the carbonator
pump
No
1. Check whether or not there is
power across the carbonator power
cord on the E-Board in the E-Box.
2. Change carbonator power cord on
the E-Board in the E-Box
No
Is the
pump motor
running
Replace carbonator
pump
Yes
No
1. Replace Carbonator
pump.
2. Check Y tting on the
total ex manifold
Yes