IDC 255 Progate Drive Thru Service Manual
Publication Number: 621057419SER - 30 - © 2006-2013, IMI Cornelius Inc.
BEVERAGE NOT DISPENSING
BEVERAGE NOT DISPENSING
Is the key switch
on/off
1. Check the key switch
Off
Is
there power on
the line side of the
transformer
On
1. Check the transformer connections
to the E-Board in the E-Box.
2. Check the E - Board in the E- Box
ensuring that power is being
supplied to the board.
No
Is
there power on the
load side of the
transformer
Yes
1. Check the transformer.
2. Change the transformer.
No
1. Check the wire harness from the beverage
valves to the terminal board.
2. Check the beverage dispense valve to ensure
that they are functioning.
3. Change beverage valve.
4. Check the water line to the valve and the syrup
line to the valve.
Yes

Table of Contents