ELECTRICAL SPECIFICATIONS
The cover requires a dedicated single phase 115 V AC (North America) or 230 V AC (Europe) hard-wired power
supply.
The cover must be installed in accordance with and comply with all applicable local codes and regulations. All
wiring and connections should be performed by a certified electrician.
Wires and cables should be sized according to local codes and regulations.
NORTH AMERICAN REQUIREMENTS
Voltage 115 V, 60 Hz (1 hot, 1 neutral, 1 ground)
GFCI 15 A single-pole GFCI (not included)
Current draw Max 12 A
EUROPEAN REQUIREMENTS
Voltage 230 V, 50 Hz (2, 1 ground)
GFCI 10 A single-pole GFCI (not included)
Current draw Max 6 A
WARNING
Covana does not allow any modifications of the electrical system. Covana reserves the right to void the warranty
if any modifications is done without its approval.
OPERATION LIMITATIONS
WARNING
The cover should never be used if the following conditions are reached.
Maximum wind
Gusts of 30 mph (50 km/h) while in the raised position and 45 mph (70 km/h)
when completely lowered on the spa.
Maximum weight on the cover
(evenly distributed)
200 lb. (90 kg)
GENERAL SPECIFICATIONS
Lifting speed 2.5 in./s (6 cm/s)
Total weight Up to 600 lb. (272 kg)
240799 OWNER'S MANUAL REVISION 4