SPECIFICATIONS (Cont’d)
CPS REFRIGERANT TANK SPECIFICATIONS (Industry Standard)
Weight Of
Empty Tank
Tank Water
Capacity
Max. Refrigerant
Weight (80% Of
Water Capacity)
Total Weight
(Tank &
Refrigerant)
Tank Foot Ring
Diameter
Tank Outside
Diameter
Tank Height
Max.
Pressure
Rating
lb kg lb kg lb kg lb kg in mm in mm in mm psig (bar)
CRX430T
30 Lb
(13.60 kg)
Included
17.5 7.9 26.2* 11.9* 20.96* 9.52* 38.46 17.42 7.8 198.1 9.5 241.3 18.1 459.7 400 (27.57)
Optional
Accessory:
CRX400T
50 Lb
(22.7 kg)
28.3 12.8 47.4 21.5 37.92* 17.2* 66.22 30.0 8 203.2 12.5 317.5 19.75 501.7 400 (27.57)
*Maximum weight of refrigerant that should be recovered
REFRIGERANT RECOVERY TANKS
• DOT Certified for refrigerant
storage
• Refrigerant compatible sealant
used on all mechanical
connection points
• Auxiliary port for optional
overfill sensor
• Liquid and Vapor UL listed
• Y-valve powder coated for
maximum rust protection
• 1/4˝ SAE Male fittings
CRX430T (FACTORY INSTALLED ON MX
SERIES MACHINES)
CRX430TB
(40/PALLET-OPTIONAL ORDER QTY)
30 lb
CRX400T (OPTIONAL SIZE TANK)
CRX400TB
(24/PALLET-OPTIONAL ORDER QTY)
50 lb
REFRIGERANT CYLINDER HEATER BLANKET (OPTIONAL ACCESSORIES)
SPECIFICATIONS
AR27XHB115-1
Voltage (Hz) 120 VAC (50/60 Hz)
Watts 340 W
Amps 2.8
For Cylinder Sizes From 8˝ (20 cm) to 14˝ (35 cm) Diameter Tanks
Control (Overheat Protection) Automatic Thermal Cutoff (Encapsulated Thermostat)
Minimum Surface Temperature Of Tank 115°F (46°C)
Maximum Thermostat Temperature 130°F (55°C)
Power Cord Length 20˝ (0.50 m)
Adjustable Velcro Strap Max Length 19˝ (0.48 m)
Heater Blanket Width 3˝ (76 mm)
Heater Blanket Length 24˝ (.60 m)
Heater Blanket Color Dark Orange
Electrical Connection Type IEC320 C15 Female Connector