“E1-BAD TXT EPROM”; A bad scale may cause this, also.
“E2-SCALE ADC”; Connection to the scale electronics lost.
“E3-SCALE EPROM”; Scale not calibrated?
“E4-CANNOT CAL”; Scale cannot be calibrated or bad calibration.
“E5-MBV FAULT: X”; Where X is a number from 1 to 5 indicating which MBV has failed.
“E6-AMB. THRM”; Ambient thermistor in the “head” is bad.
“E7-TNK THRM”; Thermistor attached to the oil sep. is bad.
“E8-PT TRANS”; Pressure transducer is bad.
“E9-WEAK BATT”; Should never appear.
“E10-BAD FILTERTIME”; Filter code problems.
“E11-DEFAULTS NOT SET”; What it says…
“E12-BAD GRAPH MEM”; Problems with the graphics like Chinese and Russian.
“E13-BAD PTR. TO INFO MEM”; Major software corruption, fatal error.
“E15 FLOW SWITCH ERROR” Air flow switch is open.
“UNKNOWN ERROR”; Cause of problem cannot be identified