2. In the base rack and each storage rack, connect an Omni-Path fabric data cable to the upper Omni-Path
switch (OPA1 in the diagrams) (available ports listed above), and then to the customer core switch.
3. In each storage rack of a multi-rack system, connect a Cat 5/6 Ethernet cable to the lower Ethernet switch
(SW0) (available ports listed above). Connect the other end of the cable to the lower Ethernet switch (SW0) in
the base rack.
4. In each storage rack of a multi-rack system, connect a Cat 5/6 Ethernet cable to the upper Ethernet switch
(SW1) (available ports listed above). Connect the other end of the cable to the upper Ethernet switch (SW1)
in the base rack.
5. In the base rack, connect a Cat 5/6 Ethernet cable from the NIC card, SMU node 0, NIC 5 to the local
network.
6. In the base rack, connect another Cat 5/6 Ethernet cable from the NIC card, SMU Node 1, NIC 5 to the local
network.
11.8
Cable SMU and Omni-path 48-Port LDN with Dual 48-Port LMN
Switches
About this task
For ClusterStor L300 and L300N inter-rack 48-port Omni-Path (OPA) switch LDN cabling, the available uplink
ports are:
Upper switch 1 (OPA1) - 17 through 48
Lower switch 0 (OPA0) - 17 through 48
For inter-rack LMN Ethernet switch cabling, the available uplink ports are:
Upper switch 1 (SW1) - ports 1 through 24, 29, 31, 41, and 43
Lower switch 0 (SW0) - ports 1 through 24, 29, 31, 41, and 43
Port 37 is the ISL and is not available
For inter-rack LMN switch cabling, the available uplink ports in the storage rack (24-port switches) are:
Upper switch 1 (SW1) - 5, 7, 17, and 19
Lower switch 0 (SW0) - 5, 7, 17, and 19
Port 13 is the ISL and is not available
IMPORTANT: Switch port assignments in the configuration diagrams are provided for reference only. For
system-specific inter-rack switch cabling, refer to the system-specific storage configuration document
(SCD).