I
CLEAR
INTERRUPT
FLAG
NO
SET
CHANNEL
LIMIT
GET
CHANNEL
INTERRUPT
NO.
DETERMINE
NUMBER
OF
WORDS
TRANSFERRED
CLEAR
INT.
ERROR
FLAGS
Figure 6-1. Basic
I/O
program
flow
chart
assembled
word.
If
a
partial
word
is
found, the
valid
portion of the
word
is
stored in
memory
and
the unreceived, lower-order parcels are stored
as
zeros.
For
the
OV
module,
(CA)
=
(CL)
causes the
I/O
interrupt
request
unless the disconnect
is
received before the
word
count
is
exhausted.
The
interrupt
flag
sets
when
a disconnect pulse
is
received or
when
an
error
condition
is
detected.
Setting
the
interrupt
flag
deactivates
the
input channel.
Input channel
error
conditions
1.
Parity
error
2240004
OJ/OK
asynchronous channel
(MCU
channel) -
The
parcel in
which
the
error
occurs will immediately
set
the channel
error
flag~
deactivate
the channel
and
generate
an
I/O
interrupt
request.
If
the
error
occurred in parcel
0,
1,
or
2,
the
last
64-bit
word
is
not
stored.
All
input ready pulses received
after
the channel
is
deactivated are
resumed
but the data parcels
are discarded.
6-4