I
When
the i designator
is
4, the
instruction
transmits the contents of
Sj
to the real-time clock
register.
When
the j designator
is
0,
the
real-
time clock
is
cleared.
If
the
Programmable
Clock
Interrupt
(PCI)
Option
is
installed,
the content
of
the k
field
is
relevant for
this
instruction.
Hold
issue conditions
034
-
037
in process
Exchange
in process
For
0010, 0011, 0012, 0013,
and
0014,
Aj
or
Sj
or
Ak
Reserved
Execution
time
Instruction issue 1
CP
Special cases
If
the
program
is
not in monitor
mode,
instruction
becomes
a
no-op
although
all
hold
issue conditions
remain
effective.
For
0010, 0011,
and
0012:
If
j =
0,
instruction
is
a
no-op
If
(Aj) < 2 or
(Aj)~
31
8
,
instruction
is
a
no-op
If
k = 0,
CA
or
CL
is
set
to 1
For
0013:
If
j = 0,
XA
register
is
cleared
For
0014:
If
j = 0,
RTC
register
is
cleared
Correct
priority
interrupting
channel
number
can
be
read (via
033
instruction)
2
CP
after
issue of
0012
instruction.
2240004
4-9
E