Chapter 5. Basic Information
Setup the PLU, Department, Table, Taste, Payment method, Tax, and other
name in this part.
5.1 PLU setup
1. Flag1 (EFGHABCD)
A=0, attribute controlled by dept;
A=8, does not controlled by any other department;
A=1, could not sold adding service charge;
A=2, Discounting is disabled;
A=4, could not change price temporary;
B=1, Sale with 0 price forbidden;
B=2, could not sale lower than cost price;
B=4, can sell the product even the stock is negative number
C=1, E-scale product;
C=4, tax included;
C=8, tax-on tax;
D=1, link to tax1;
D=2, link to tax2;
D=4, link to tax3;
D=8, link to tax4.
2. Flag2 or Attribute2 is used to define the kitchen printer. (EFGHABCD)
A=1, connect to kitchen printer;
A=4, connect to the main printer;
A=8, function does not controlled by dept;
C, is the print port no.
C=1, printer port no. is 1
C=2, printer port no. is 2
E, send to label printer.