4 — PROGRAMMABLE PARAMETERS
pg. 31
Table 3 Programmable Parameters Menus: 1313/1314 Programmer
continued
DRIVERS MENU........................ p. 54
— MAIN CONTACTOR....... p. 54
— Main Enable
— Main Interlock Type
— Pull In Voltage
Holding Voltage
— Battery Voltage Comp
Interlock Type
— Open Delay
Weld Check Enable
We ld Check On Open
Enable
— Main DNC Check Enable
— Precharge Enable
— DRIVER 3..................... p. 56
— Pull In Voltage
Holding Voltage
EM BRAKE CONTROL MENU..... p. 52
Brake Type
— Pull In Voltage
Holding Voltage
— Battery Voltage Comp
— Set EM Brake On Fault
— Zero Speed Threshold
Zero Speed Threshold Time
Position Hold Settling Time
Brake Set Time
Torque Release Time
Brake Release Time
Torque Preload Time
Torque Preload Enable
Save Torque Preload
Torque Preload Cancel Delay
— EM Brake Fault Motor Revs
EM BRAKE TEST MENU............. p.54
— Mode
— Direction
— Current
Ramp Time
— Test Threshold
Hold Time
— Max Speed Limit
— Hill Compensation Enable
— FAULT CHECKING........................... p. 56
— Driver1 Checks Enable
— Driver2 Checks Enable
— Driver3 Checks Enable
— Driver4 Checks Enable
— PD Checks Enable
— External Supply Max
— External Supply Min
— PWM FREQUENCY........................... p. 56
MOTOR MENU........................................ p. 57
Typical Max Speed
Motor Technology
— 0 - INDUCTION MOTOR (ACIM) ........ p. 58
— CHARACTERIZATION TESTS ....... p. 58
— Test Enable
— Test Throttle
— Motor Poles
— Max Test Speed
— Max Text Current
— SlipGain
— Current Reg Tuning Test Enable
— FIELD WEAKENING CONTROL..... p. 59
— FW Base Speed
— Field Weakening Drive
Weakening Rate Drive
— Min Field Current
— Swap Two Phases
— Swap Feedback Direction
— MotorType
LOS (LIMITED OPERATING
STRATEGY)........................ p. 61
— LOS Upon Encoder Fault
— LOS Max Speed
— LOS Max Current
— LOS Max Mod Depth
— LOS Accel Rate
— LOS Decel Rate
1 - P MAC (PERMANENT MAGNET
MOTOR)............................ p. 62
COMMISSIONING TESTS........... p. 62
Typical Max Speed
— Max Test Speed
Motor Type
— Test Enable
— Test Throttle
— Swap Direction
— Max Test Current
FIELD WEAKENING CONTROL...... p. 63
— Field Weakening Rate
— FW Current Limit (Apk)
Motor Type
— Restricted Operation
COMMISSIONING RESULTS......... p. 64
— Tuning Voltage
— Short Circuit Current (RMS)
— Phasing Mode
— Sensor Position Offset
— Sensor Compensation Factor
— Kp d Axis Current
— Ki d Axis Current
— Kp q Axis Current
— Ki q Axis Current
— Sin Min
— Sin Max
— Cos Min
— Cos Max
— Rsys
— Commissioning Needed
— FEEDBACK OPTIONS......................... p. 65
Feedback Type
— 1 - QUADRATURE ENCODER............... p. 65
— Encoder Steps
— SPEED FILTERS.............................. p. 65
— Speed Filter
— Speed Filter Zero Speed
— 2 - SIN/COS....................................... p. 66
— Enable Multiturn Sensor
— Sin Cos Fault Threshold
— Sin Cos fault Threshold High
— Sin Cos Fault Time
— Sin Cos Startup Time
— Sin Min

Table of Contents

Related product manuals