EasyManua.ls Logo

Curtis 1239E - 0 - SPEED MODE EXPRESS - SPEED MODE EXPRESS MENU

Curtis 1239E
160 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Return to TOC Curtis 1239E-1269E Manual, os 37.0 RevA – May 2021
4 — PROGRAMMABLE PARAMETERS
pg. 31
Table 3 Programmable Parameters Menus: 1313/1314 Programmer
continued
DRIVERS MENU........................ p. 54
— MAIN CONTACTOR....... p. 54
— Main Enable
— Main Interlock Type
— Pull In Voltage
— Holding Voltage
— Battery Voltage Comp
— Interlock Type
— Open Delay
— Weld Check Enable
— We ld Check On Open
Enable
— Main DNC Check Enable
— Precharge Enable
— DRIVER 3..................... p. 56
— Pull In Voltage
— Holding Voltage
EM BRAKE CONTROL MENU..... p. 52
— Brake Type
— Pull In Voltage
— Holding Voltage
— Battery Voltage Comp
— Set EM Brake On Fault
— Zero Speed Threshold
— Zero Speed Threshold Time
— Position Hold Settling Time
— Brake Set Time
— Torque Release Time
— Brake Release Time
— Torque Preload Time
— Torque Preload Enable
— Save Torque Preload
— Torque Preload Cancel Delay
— EM Brake Fault Motor Revs
EM BRAKE TEST MENU............. p.54
— Mode
— Direction
— Current
— Ramp Time
— Test Threshold
— Hold Time
— Max Speed Limit
— Hill Compensation Enable
— FAULT CHECKING........................... p. 56
— Driver1 Checks Enable
— Driver2 Checks Enable
— Driver3 Checks Enable
— Driver4 Checks Enable
— PD Checks Enable
— External Supply Max
— External Supply Min
— PWM FREQUENCY........................... p. 56
MOTOR MENU........................................ p. 57
— Typical Max Speed
— Motor Technology
— 0 - INDUCTION MOTOR (ACIM) ........ p. 58
— CHARACTERIZATION TESTS ....... p. 58
— Test Enable
— Test Throttle
— Motor Poles
— Max Test Speed
— Max Text Current
— SlipGain
— Current Reg Tuning Test Enable
— FIELD WEAKENING CONTROL..... p. 59
— FW Base Speed
— Field Weakening Drive
— Weakening Rate Drive
— Min Field Current
— Swap Two Phases
— Swap Feedback Direction
— MotorType
— LOS (LIMITED OPERATING
STRATEGY)........................ p. 61
— LOS Upon Encoder Fault
— LOS Max Speed
— LOS Max Current
— LOS Max Mod Depth
— LOS Accel Rate
— LOS Decel Rate
— 1 - P MAC (PERMANENT MAGNET
MOTOR)............................ p. 62
— COMMISSIONING TESTS........... p. 62
— Typical Max Speed
— Max Test Speed
— Motor Type
— Test Enable
— Test Throttle
— Swap Direction
— Max Test Current
— FIELD WEAKENING CONTROL...... p. 63
— Field Weakening Rate
— FW Current Limit (Apk)
— Motor Type
— Restricted Operation
— COMMISSIONING RESULTS......... p. 64
— Tuning Voltage
— Short Circuit Current (RMS)
— Phasing Mode
— Sensor Position Offset
— Sensor Compensation Factor
— Kp d Axis Current
— Ki d Axis Current
— Kp q Axis Current
— Ki q Axis Current
— Sin Min
— Sin Max
— Cos Min
— Cos Max
— Rsys
— Commissioning Needed
— FEEDBACK OPTIONS......................... p. 65
— Feedback Type
— 1 - QUADRATURE ENCODER............... p. 65
— Encoder Steps
— SPEED FILTERS.............................. p. 65
— Speed Filter
— Speed Filter Zero Speed
— 2 - SIN/COS....................................... p. 66
— Enable Multiturn Sensor
— Sin Cos Fault Threshold
— Sin Cos fault Threshold High
— Sin Cos Fault Time
— Sin Cos Startup Time
— Sin Min

Table of Contents