EasyManua.ls Logo

Curtis MultiMode 1207B - Page 45

Curtis MultiMode 1207B
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 9 J U N E 2 0 1 2 D R A F T
APPENDIX A: GLOSSARY
Curtis 1207B Manual
A-13
APPENDIX B: SPECIFICATIONS
B-1
SPECIFICATIONS: 1207B CONTROLLERS
Nominal input voltage 24 V
Maximum operating voltage 30 V
Overvoltage point 33 V
Minimum operating voltage 16 V (= undervoltage point)
Electrical isolation to heatsink 500 V ac (minimum)
PWM operating frequency 15 kHz
Output current
*
1207B-41XX 1207B-51XX
250 amps for 1 minute 300 amps for 30 seconds
200 amps for 2 minutes 210 amps for 2 minutes
150 amps for 5 minutes 160 amps for 5 minutes
100 amps for 1 hour 110 amps for 1 hour
Contactor voltage 24 V
Contactor current (maximum) 1 amp (current limit at 2 amps)
Contactor coil spike protection internal diode to brake; internal diode from brake to KSI
Shunt driver current (maximum) 2 amps
Shunt driver spike protection active clamp at 47 V
KSI input voltage 16 30 V
KSI input current (typical) 80 mA without programmer; 130 mA with programmer
Logic input current (typical) 10 mA at 24 V
Logic input threshold 8 V
Ambient operating temperature range -25°C to 50°C
Heatsink overtemperature cutback 85°C
Heatsink undertemperature cutback -25°C
Package splash resistant
Weight 1.1 kg (2.5 lbs)
Dimensions 122
× 165 × 66 mm (4.8" × 6.5" × 2.6")
*
Output current rating test conditions:
1. Controller cover installed
2. Controller mounted to 230
× 305 × 3.2 mm (9" × 12" × 0.125") aluminum plate heatsink
3. Airflow at 4.8 km/h (3 mph) perpendicular to bottom of aluminum plate
4. Duty factor held at 60%
5. Initial heatsink temperature at 20°C
6. Ambient temperature at 20°C
7. Current held at tested rating for 120% of time before thermal cutback.

Table of Contents

Related product manuals