PAGE 44 USER GUIDE DNC 60 GS
3) Enter:
value
1 in the field
Clear variables zone
,
value
1 in the field
Clear machine parameters zone
and value
817 in the field
EXECUTION CODE
.
Press the
key.
Press the
key twice.
4) Enter:
value 1 in the field
Clear variables zone
,
value
1 in the field
Clear machine parameters zone
,
value
1 in the field
Clear transmission RS232 zone
and value
817 in the field
EXECUTION CODE
.
Press the
key.
Press the
key twice.
The clearing of the machine parameters deletes also all the input / output
configuration defined by the operator.
It is therefore advisable to re-configure the DNC 60 before the next use.
Attention: If you use an external system for the data reintroducing
(LINK 7000, CYBACK via RS232) and the problem persists, then the
informations re-entered by this system have to be called into question.
The best to do in this case is to delete again the whole contents of the DNC
and to re-program the DNC manually via the keyboard (not the RS232 line).