DGS-1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide
463
PSE cannot monitor the valid MPS of PD on the PI.
Overload
If the PD is drawing too much power to exceed the maximum output
power that the port can supply, then the overload counter is
increased.
Short
If the PD’s internal circuit is shorted for some reason, then this
counter is increased.
Power Denied
If the PoE software system decides to disallow providing power to
the attached PD, then this counter is increased.
Invalid Signature
Increased if the PSE detects a PD who has an invalid PD signature.
Example
This example shows how to display the PoE power inline measurement.
Switch# show poe power-inline measurement
Interface Voltage(V) Current(mA) Temperature(C) Power(W)
--------- ---------- ----------- -------------- --------
eth3/0/1 54.2 109 35 5.9
eth3/0/2 55 196 38 10.8
!--- Output suppressed.
eth4/0/1 54.6 197 32 10.7
eth4/0/2 54.8 286 36 15.7
eth4/0/3 n/a n/a n/a n/a
eth4/0/4 n/a n/a n/a n/a
!--- Output suppressed.
eth5/0/24 n/a n/a n/a n/a
eth5/0/25 n/a n/a n/a n/a
Switch#
This example shows how to display the PoE power inline LLDP classification.