DGS-1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide
675
RX power
high-low: High or low threshold.
Event description: when the any of SFP parameters exceeds from the alarm
threshold.
Log Message: Optical transceiver <interface-id> <component> <high-low>
alarm threshold exceeded.
Parameters description:
interface-id: port interface ID.
component: DDM threshold type. It can be one of the following types:
temperature
supply voltage
bias current
TX power
RX power
high-low: High or low threshold.
Event description: when the any of SFP parameters recovers from the warning
threshold.
Log Message: Optical transceiver <interface-id> <component> back to normal.
Parameters description:
interface-id: port interface ID.
component: DDM threshold type. It can be one of the following types:
temperature
supply voltage
bias current
TX power
RX power
Event description: DHCPv6 client interface administrator state changed.
Log Message: DHCPv6 client on interface <ipif-name> changed state to
[enabled | disabled].
Parameters description:
<ipif-name>: Name of the DHCPv6 client interface.
Event description: DHCPv6 client obtains an ipv6 address from a DHCPv6
server.
Log Message: DHCPv6 client obtains an ipv6 address < ipv6address > on
interface <ipif-name>.
Parameters description:
ipv6address: ipv6 address obtained from a DHCPv6 server.
ipif-name: Name of the DHCPv6 client interface.
Event description: The ipv6 address obtained from a DHCPv6 server starts
renewing.
Log Message: The IPv6 address < ipv6address > on interface <ipif-name>
starts renewing.
Parameters description:
ipv6address: ipv6 address obtained from a DHCPv6 server.
ipif-name: Name of the DHCPv6 client interface.
Event description: The ipv6 address obtained from a DHCPv6 server renews
success.
Log Message: The IPv6 address < ipv6address > on interface <ipif-name>