AUTOMATIC ENGINE SHUT
OFF
(1) Alarm switch for straw discharge
The straw discharge alarm switch
is on; alarm sounds continuously
and the engine is shut off.
ALARM SWITCH FOR STRAW
DISCHARGE
E32O701A
When the straw discharging con-
veyer chain or straw cutter is
clogged, the clog shuts off the en-
gine automatically.
When cutting, if the straw can
not be discharged at the cutting
position, the alarm light switch is
started when there is load on the
switching cover.
(1) Emergency shut-off switch
For emergencies such as manual
threshing, the emergency shut-off
switch should be pushed. When
the emergency shut-off switch is
pressed and the engine is shut off,
please turn the start key to the po-
sition of “stop” and restart it.
STRAW TREATMENT SELEC
-
TION LEVER
(1) Alarm switch for cutting blockage
(2) Switching cover
(3) Supporting plate
E32O406A
E32O407A
ALARM SWITCH FOR CUTTING
BLOCKAGE