Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - October 31, 2013
Rev. 5
Page 3.3.3
Engine failure in flight
Symptoms : Loss of power
Fly the airplane
1 - FUEL TANK SELECTOR Switch tanks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 - AUX BP switch ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 - Autopilot Disconnect. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If power recovery successful :
4 - Remaining fuel Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Land as soon as possible
End of procedure
If power recovery unsuccessful :
5 - THROTTLE CUT OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 - Oxygen masks Use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 - Air start envelope Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Refer to chapter 3.4
End of procedure.