Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - October 31, 2013
Rev. 4
Page 3.5.5
Smoke elimination
1 - Oxygen masks and goggles Use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 - BLEED switch OFF / RST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 - A/C switch OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 - DUMP switch Actuate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 - Wait until the differential pressure drops.
6 - EMERGENCY RAM AIR control knob Pull. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If smoke decreases :
► Land as soon as possible ◄
End of procedure ■
If smoke increases :
7 - EMERGENCY RAM AIR control knob Push. . . . . . . . . . . . . . . . . . . . . .
► Land as soon as possible ◄
End of procedure.