Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - October 31, 2013
Rev. 4
Page 3.9.2
ESI-2000 failures 2/2
► Continuing
If in visual meteorological conditions :
2 - Cycle power on ESI-2000, including internal power.
3 - Maintain straight and level while unit aligns.
If red ”X” reappears :
4 - Remain clear of IMC.
End of procedure ■
Amber X’d battery symbol displayed in flight :
Indicates internal battery is not available. Battery temperature abo
ve 55°C.
1 - Reduce temperature of cockpit environment.
2 - Remain clear of IMC until amber ”X” is removed from the display.
End of procedure ■
Amber battery symbol displayed in flight :
Indicates the internal battery state of charge is low.
1 - Remain clear of IMC until amber battery symbol is removed from the
display signifying battery is charged sufficiently to have one hour of
discharge abilitiy.
End of procedure ■
ESI-2000 in-flight shutdown (manual procedure) :
1 - Maintain control of the airplane using airplane primary instruments.
2 - STBY INSTR breaker Pull. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
To remove all airplane power to the ESI-2000
3 - Press any key (button) as stated by the on screen message.
4 - M (Menu) button Press repeatedly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Until Shutdown menu is shown
5 - + (Hold) button Press
and hold. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Until SHUTTING DN message is shown
in the upper left corner of the screen
End of procedure.