Cabin not depressurized after landing
If ΔP cabin remains > 0 :
1 - DUMP switch Actuate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 - BLEED switch OFF / RST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If necessary :
3 - EMERGENCY RAM AIR control knob Pull. . . . . . . . . . . . . . . . . .
4 - Wait for complete cabin depressurization before opening any door.