VACUUM LOW
Low vacuum may lead to malfunctioning of leading edge deicing and pressurization.
1 - Monitor the normal functioning of leading edge deicing and pressurization.
If necessary :
2 - Altitude Below 10000 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 - Return to VMC conditions as soon as possible.
► Fly the airplane ◄
4 - BLEED switch OFF / RST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
End of procedure.