Pilot's Operating Handbook
Section 4
Normal procedures
EASA Approved
Edition 0 - October 31, 2013
Rev. 4
Page 4.4.26
Engine start 3/3
Continuing
When
- Ng > 50 % and,
- 1 minute max :
CAUTION
If the starter does not go off automatically, disengage it using the
ABORT position of the STARTER switch.
16 - Starter Check OFF automatically. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17 - STARTER Check OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18 - Engine parameters Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Check 54 % Ng 58 %, oil pressure and ITT in green sector
End of procedure.