Pilot's Operating Handbook
Section 4
Normal procedures
EASA Approved
Edition 0 - October 31, 2013
Rev. 4
Page 4.4.32
Motoring followed by an engine start 3/3
► Continuing
Fuel panel
24 - AUX BP switch AUTO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25 - AUX BOOST PMP ON Check OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electric power
26 - MAIN GEN Check OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reset if necessary
● NOTE ●
MAIN GEN normally goes off as soon as STARTER goes off.
●
If MAIN GEN does not go off :
27 - Ng Increase over 70 %. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
To start main generator
28 - Generator and battery AMPS Check charge. . . . . . . . . . . . . . . . . . . . .
On EIS of MFD
29 - Battery and ESS. bus VOLTS Check voltage ≈ 28 Volts. . . . . . . . . . .
On EIS of MFD
End of procedure.