EasyManua.ls Logo

Daher TBM 900 - Page 271

Default Icon
996 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pilot's Operating Handbook
Section 4
Normal procedures
EASA Approved
Edition 0 - October 31, 2013
Rev. 4
Page 4.4.32
Motoring followed by an engine start 3/3
Continuing
Fuel panel
24 - AUX BP switch AUTO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25 - AUX BOOST PMP ON Check OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electric power
26 - MAIN GEN Check OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reset if necessary
NOTE
MAIN GEN normally goes off as soon as STARTER goes off.
If MAIN GEN does not go off :
27 - Ng Increase over 70 %. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
To start main generator
28 - Generator and battery AMPS Check charge. . . . . . . . . . . . . . . . . . . . .
On EIS of MFD
29 - Battery and ESS. bus VOLTS Check voltage 28 Volts. . . . . . . . . . .
On EIS of MFD
End of procedure.
PIM - DO NOT USE FOR FLIGHT OPERATIONS

Table of Contents

Related product manuals