Pilot's Operating Handbook
Section 4
Normal procedures
EASA Approved
Edition 0 - October 31, 2013
Rev. 4
Page 4.4.67
Shutdown 2/2
Continuing
16 - AUX BP switch OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17 - GENERATOR selector OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
When inertial separator is retracted, after approximately 40 sec :
18 - SOURCE selector OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19 - Crash lever Pull down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20 - FUEL TANK SELECTOR OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21 - PARK BRAKE As required. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CAUTION
In case of high OAT [above 35°C (95°F)], it is required to perform
30 sec dry motoring run after shutdown to improve cooling of the
bearing cavities and minimize oil coking - refer to procedure Motoring.
Shutdown stand-by instruments
ESI-2000 normal shutdown procedure :
22 - No pilot action required for normal shutdown. The ESI-2000 will
shut down within 5 minutes.
ESI-2000 manual shutdown procedure :
NOTE
The ESI-2000 can be manually shut down when in the discharge mode to
conserve battery power.
23 - Remove all airplane power from the ESI-2000.
24 - Press any key as stated by the on screen message.
25 - Press the M key repeatedly until shutdown menu is shown.
26 - Press and hold the + key until SHUTTING DN message is shown
in the upper left corner of the screen.
End of procedure.
PIM - DO NOT USE FOR FLIGHT OPERATIONS

Table of Contents