Pilot's Operating Handbook
Section 8
Handling, servicing and maintenance
Edition 0 - October 31, 2013
Rev. 4
Page 8.7.10
If the pressure on the oxygen cylinder gage is low :
Fil
l the oxygen cylinder
5 - Make sure the area around the oxygen cylinder charging valve is clean.
Remove the cap from the charging valve.
6 - Make sure the oxygen supply hose is clean and connect it to the
charging valve.
7 - Slowly pressurize the oxygen cylinder to the correct pressure.
8 - Close the oxygen supply and let the cylinder temperature become
stable.
9 - Monitor the oxygen pressure on thegage and fillto the correct pressureif
necessary.
10 - Release the pressure in the oxygen supply hose and disconnect from
the charging valve.
11 - Install the cap on the charging valve.
12 - Make sure all the tools and materials are removed and the work area is
clean and free from debris.
13 - Close the oxygen service door.