User's Manual
238
Figure 5-203 Temperature/Humidity
Step 2 On the temperature information line, click .
Figure 5-204 Setting
Step 3 Configure the settings for alarm linkage.
Table 5-50 Alarm linkage settings
Parameter Description
Access Point Indicates the channel that the camera is connected to.
Type
Temperature
by default.
Detect Position Name Set the detect position name.
Preview Channel
Select the channel that you want to preview to help monitor the
channel of access point. This channel could be the channel of
access point or any other channels according to your actual
situation.
Event Type
Select event type as
High
or
Low
, and set the upper and low