EasyManua.ls Logo

Daikin BRC1E63 - Key Lock; Precautions for Setting Cool;Heat Selection Eligibility

Daikin BRC1E63
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
Precautions for Setting Cool/Heat Selection Eligibility
The cool/heat selection eligibility needs to be set for a single remote controller in the following
case.
(Heat Pump System) (Heat Recovery System)
Indoor unit Indoor unit
A number of indoor units are
connected to a single outdoor unit.
Set the Cool/Heat/Fan mode selection
eligibility in one of the remote controllers.
A number of indoor units are
connected to a single BS unit.
Set the Cool/Heat/Auto/Fan mode selection
eligibility in one of the remote controllers.
BS (Branch Selector) unit:
The BS unit is used for cool or
heat mode selection.
Key Lock
Operation
Make settings and cancel settings in the Basic screen.
1
Cool
Basic screen
Continue pressing Menu/Enter button for at least
4seconds. (During backlight lit)
2
Cool
” will appear.
All buttons are disabled when the keys are locked.
To cancel the Key lock, continue pressing
Menu/Enter button for at least 4seconds. (During
backlight lit)
Set to
28°C
Set to
28°C

Table of Contents