Si01-501 Specifications
Specifications 7
50Hz 220V
Note:
MAX. interunit piping length: 25m
MAX. interunit height difference: 15m
Amount of additional charge of refrigerant 20g/m for piping length exceeding 10m
The data are based on the conditions shown in the table below.
Models
Indoor Units FT15DV2S
Outdoor Units R15DV2S
Capacity (Rated)
kW 4.2
Btu/h 14,400
kcal/h 3,620
Moisture Removal L/h 1.9
Running Current (Rated) A 5.88
Power Consumption (Rated) W 1,270
Power Factor % 98.2
COP (Rated) W/W 3.31
Piping
Connections
Liquid mm φ 6.4
Gas mm φ12.7
Drain mm φ18.0
Heat Insulation Both Liquid and Gas Pipes
Indoor Units FT15DV2S
Front Panel Color White
Air Flow Rate
m³/min
(cfm)
H 18.5(653)
M 15.1(533)
L 11.6(409)
Fan
Type Cross Flow Fan
Motor Output W 43
Speed Steps 5 Steps, Auto
Air Direction Control Right, Left, Horizontal, Downward
Air Filter Removable/Washable/Mildew Proof
Running Current A 0.23
Power Consumption W 50
Power Factor % 98.8
Temperature Control Microcomputer Control
Dimensions (H×W×D) mm 290×1,050×238
Packaged Dimensions (H×W×D) mm 337×1,147×366
Weight kg 12
Gross Weight kg 17
Operation
Sound
H/L dBA 45/34
Outdoor Units R15DV2S
Casing Color Ivory White
Compressor
Type Hermetically Sealed Rotary Type
Model RC46AV1TRT
Motor Output W 1,100
Refrigerant
Oil
Type SUNISO 4GSD. I.
Charge L 0.5
Refrigerant
Type R22
Charge kg 1.25
Air Flow Rate
m³/min 28
cfm 988
Fan
Type Propeller
Motor Output W 27
Running Current (Rated) A 5.65
Power Consumption (Rated) W 1,220
Power Factor % 98.1
Starting Current A 29
Dimensions (H×W×D) mm 540×750×270
Packaged Dimensions (H×W×D) mm 609×940×360
Weight kg 37
Gross Weight kg 41
Operation Sound dBA 48
Drawing No. 3D049256
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
7.5m