FT09/13DV2S, FT25/35DVM, FT25/35DSG Si01-501
174 Removal Procedure
1.10 Removal of Fan Rotor
Procedure Warning Be sure to turn off all power supplies at least 10 min. before
disassembling work.
Step Procedure Points
1. Removing the drip proof
plate
Preparation
Remove the heat exchanger
according to the “Removal
of Heat Exchanger.”
1
Dismount the drip proof
plate (right) by
removing the 2 screws.
2
Unhook the fan motor
wire harness.
3
Remove the 2 screws
of the fan motor fixing
plate.