R25/35DV1 Si01-501
198 Removal Procedure
3.3 Removal of Electrical Device Mounting Plate
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Removing the shelter.
1
Remove the three fixed
screws for removing the
shelter.
2
Remove the shelter.
2. Removing the switch box.
1
Remove all the harness.
2
Remove two fixing
screws of electrical
device mounting plate.
3
Remove the electrical
device mounting plate.