Si01-501 FT09/13DV2S, FT25/35DVM, FT25/35DSG
Removal Procedure 165
1.7 Removal of Drain Pan Unit
Procedure Warning Be sure to turn off all power supplies at least 10 min. before
disassembling work.
Step Procedure Points
1. Removing the drain pan
unit
Preparation
Remove the electrical box
according to the “Removal
of Electrical Box.
Inserting of the wooden
base facilitates the removing
work.
Place a plastic bag under
the drain pan to prevent
from wetting the floor with
remaining drain.
1
Lift up the indoor unit
body slightly and pull
out the drain hose. (In
the case of left piping)
2
Remove the screw at
the left side of the drain
pan.
3
Remove the drain pan
from the heat
exchanger by pressing
its right side and
twisting its left side.