EasyManuals Logo

Daikin FT25DVM Service Manual

Daikin FT25DVM
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #259 background imageLoading...
Page #259 background image
Wiring Diagrams Si01-501
250 Appendix
R35DSG
R50DSG
FIELD WIRING.
indoor
X1M
2
3
L
N
1
F1S
3.15A
F1U
14
6
2
A2
K1M
13
A1
5
1
C12R
C11R
X11A
S
R
C
outdoor
M
1~
M
1~
M1C
M1F
POWER SUPPLY
~230V50Hz
NOTE
REFER TO THE NAMEPLATE FOR
THE POWER REQUIREMENTS.
WHT
YLW
RED
BLK
RED
BLK
BLK
RED
BLK
RED
WHT
BLU
RED
BLK
BLK
RED
BLK
BLU
C11R, C12R : RUNNING CAPACITOR
F1S : SURGE ARRESTER
K1M : COMPRESSOR RELAY F1U : FUSE
L : LIVE M1F : FAN MOTOR
N : NEUTRAL X1M : TERMINAL STRIP
M1C : COMPRESSOR MOTOR X11A : CONNECTOR PROTECTIVE EARTH
3D048819
L : LIVE
C11R
,
C12R : RUNNING CAPACITOR
F1U : FUSE
F1S : SURGE ARRESTER
K1M : COMPRESSOR RELAY
M1C : COMPRESSOR MOTOR
TO INDOOR UNIT
POWER SUPPLY
X1M
N
L
3
2
1
BLK
N : NEUTRAL
Q1L : OVERLOAD PROTECTOR
M1F : FAN MOTOR
X1M : TERMINAL STRIP
X11A : CONNECTOR
RED
RED
F1S
BLK
BLK
3.15A
F1U
WHT
RED
RED
BLK
Q1L
13
A1
5
1
ORG
K1M
NOTES
1. REFER TO THE NAMEPLATE FOR
A2
14
6
2
THE POWER REQUIREMENTS.
RED
RED
C12R
C11R
BLU
WHT
BLK
RED
YLW
RED
X11A
S
M
C
1~
1~
M
M
M1F
M1C
3D040743A