EasyManua.ls Logo

Daikin Sky Air R-407C - Malfunctioning Indoor PCB (A1)

Daikin Sky Air R-407C
304 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Error Codes: Indoor Units ESIE02–01
3–22 Part 3 – Troubleshooting
3
1
3
4
5
2.2 Malfunctioning Indoor PCB (A1)
Error code A1
LED indications The table below shows the LED indications.
Error generation The error is generated when the data from the EEPROM is not received correctly.
EEPROM (Electrically Erasable Programmable Read Only Memory): A memory chip that holds its
content without power. It can be erased, either within the computer or externally and usually requires
more voltage for erasure than the common +5 volts used in logic circuits. It functions like non-volatile
RAM, but writing to EEPROM is slower than writing to RAM.
Causes The possible cause is a malfunctioning indoor PCB.
Troubleshooting To troubleshoot, proceed as follows:
Operation HAP (green) HBP (green)
Normal 66
Malfunctioning
6 7
68
7
8
Switch the power off and
on again to restart.
Normal reset?
Replace indoor
PCB.
No
The malfunction may be caused by an
external factor, rather than damaged parts.
Locate the cause and correct the situation.
Yes

Table of Contents