Spyder 3 CL User's Manual 45
DALSA 03-032-20008-00
7 Appendix A
7.1 Spyder 3 Camera Link ASCII Commands
Serial Protocol Defaults
8 data bits
1 stop bit
No parity
No flow control
9.6kbps
Camera does not echo characters
Command Format
When entering commands, remember that:
A carriage return <CR> ends each command.
The camera will answer each command with either <CR><LF> “OK >" or
<CR><LF>"Error xx: Error Message >" or “Warning xx: Warning Message”. The ">"
is always the last character sent by the camera.
The following parameter conventions are used in the manual:
i = integer value
f = real number
m = member of a set
s = string
t = tap id
x = pixel column number
y = pixel row number
Example: to return the current camera settings
gcp <CR>

Table of Contents