74 Spyder 3 CL User's Manual
03-032-20008-00 DALSA
Syntax:
rpc
Notes: The digital offset is not reset.
Rebooting the Camera
The command rc reboots the camera. The camera starts up with the last saved settings
and the baud rate used before reboot. Previously saved pixel coefficients are also
restored.
7.9 Diagnostics
Generating a Test Pattern
Purpose: Generates a test pattern to aid in system debugging. The test
patterns are useful for verifying camera timing and connections.
The following tables show each available test pattern.
Syntax:
svm i
Syntax Elements:
i
svm
0
Video.
svm
smm
1
0
12 bit test pattern.
2 tap model:
svm
smm
1
1