Spyder 3 CL User's Manual 89
DALSA 03-032-20008-00
Mnemonic Syntax Parameters
Description
get prnu coeff
gpc
x
Read the PRNU coefficient.
x = pixel number to read in a range
from
1 – sensor pixel count.
get signal frequency
gsf
i
Reads the requested Camera Link
control frequency.
1 = EXSYNC frequency
2 = Spare
3 = Direction
get status led
gsl
Returns the current state of the
camera’s LED where:
1 = Red
2 = Green
5 = Blinking green
6 = Blinking red
help
h
Display the online help. Refer to the
Select Cable Camera ASCII Command
Help for details.
load pixel coefficients
lpc
i
Loads the previously saved pixel
coefficients from non-volatile memory
where
i is:
0 = Factory calibrated coefficients
1 = Coefficient set one
2 = Coefficient set two
3 = Coefficient set three
4 = Coefficient set four
reset camera
rc
Resets the entire camera (reboot). Baud
rate is not reset and reboots with the
value last used.
restore factory settings
rfs
Restores the camera’s factory settings.
FPN and PRNU coefficients reset to 0.
region of interest
roi
x y x y
Sets the pixel range affected by the cag,
gl, gla, ccf, and ccp commands. The
parameters are the pixel start and end
values (
x) and the column start and end
values (
y) in a range from 1 to sensor
pixel count
.
reset pixel coeffs
rpc
Resets the pixel coefficients to 0.
restore user settings
rus
Restores the camera's last saved user
settings and FPN and PRNU
coefficients.
set analog gain
sag
t f
Sets the analog gain in dB.
t = tap selection, either 1 or 2
depending on camera model, or
0 for
all taps.
f= gain value specified from –10 to
+10