EasyManuals Logo

Dalsa S3-10-01k40-R User Manual

Dalsa S3-10-01k40-R
115 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #80 background imageLoading...
Page #80 background image
80 Spyder 3 CL User's Manual
03-032-20008-00 DALSA
Mirroring Mode 0, left to right
Tap readout direction:
left to right, or right to
left. Set with the
smm
command.
Readout Mode Off
Current readout mode
status. Set using the
srm command.
Cable Parameter 200
The cable parameter.
Set using the
scb
command.
Exposure Mode: 2
Current exposure mode
value set with the
sem
command. See the
Setting the Camera Link
Mode section for
details.
SYNC Frequency: 5000 Hz
Current line rate. Value
is set with the
ssf
command. See the
Setting the Camera Link
Mode section for
details.
Exposure Time: 200 uSec
Current exposure time
setting. Value is set
with the
set command.
See the Setting the
Camera Link Mode
section for details.
CCD Direction: internal/forward
Current direction
setting set with scd
command. Refer to
section
CCD Shift
Direction for details.
Horizontal Binning: 1
Current horizontal
binning factor set with
the
sbh command.
Video Mode: video
Current video mode
value set with the
svm
command. See section
Generating a Test
Pattern for details.
Region of Interest: (1,1) to (1024, 1)
Region of interest size
set with the
roi
command. See section
Setting a Region of
Interest (ROI) for
details.
End-Of-Line Sequence: on
States whether an end
of line sequence is
turned on or off. Set
using the
els
command. See section
7.6 End-of-line
Sequence for details.
FFC Coefficient Set: 0
Current pixel coefficient
set loaded. Refer to

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dalsa S3-10-01k40-R and is the answer not in the manual?

Dalsa S3-10-01k40-R Specifications

General IconGeneral
BrandDalsa
ModelS3-10-01k40-R
CategoryDigital Camera
LanguageEnglish