5 How to Install
5.1 Mechanical Dimensions
5.1.1 Frequency Converter Dimensions
A
a
b
B
C
D
130BB614.10
e
f
a
d
e
130BC205.10
e
f
a
e
130BC246.10
Enclosure Power [kW] Height [mm] Width [mm] Depth
[mm]
Mounting hole
[mm]
Max.
Weight
Frame IP
Class
3x200-240
V
3x380-480
V
3x525-600 V A
A
1
a B b C d e f kg
H1 IP20 0.25-1.5 0.37-1.5 195 273 183 75 56 168 9 4.5 5.3 2.1
H2 IP20 2.2 2.2-4.0 227 303 212 90 65 190 11 5.5 7.4 3.4
H3 IP20 3.7 5.5-7.5 255 329 240 100 74 206 11 5.5 8.1 4.5
H4 IP20 5.5-7.5 11-15 296 359 275 135 105 241 12.6 7 8.4 7.9
H5 IP20 11 18.5-22 334 402 314 150 120 255 12.6 7 8.5 9.5
H6 IP20 15-18.5 30-45 18.5-30 518 595/635
(45 kW)
495 239 200 242 - 8.5 15 24.5
H7 IP20 22-30 55-75 37-55 550 630/690
(75 kW)
521 313 270 335 - 8.5 17 36
H8 IP20 37-45 90 75-90 660 800 631 375 330 335 - 8.5 17 51
H9 IP20 2.2-7.5 269 374 257 130 110 205 11 5.5 9 6.6
H10 IP20 11-15 399 419 380 165 140 248 12 6.8 7.5 12
I2 IP54 0.75-4.0 332 - 318.5 115 74 225 11 5.5 9 5.3
I3 IP54 5.5-7.5 368 - 354 135 89 237 12 6.5 9.5 7.2
I4 IP54 11-18.5 476 - 460 180 133 290 12 6.5 9.5 13.8
I6 IP54 22-37 650 - 624 242 210 260 19 9 9 27
I7 IP54 45-55 680 - 648 308 272 310 19 9 9.8 45
I8 IP54 75-90 770 - 739 370 334 335 19 9 9.8 65
Table 5.1 Dimensions