0-43 [Reset] Key on LCP
Option: Function:
[7] Enabled
without OFF
[8] Password
without OFF
6.4.5 0-5* Copy/Save
Copy parameters from and to the LCP. Use these
parameters for saving and copying set-ups from one unit
to another.
0-50 LCP Copy
Option: Function:
[0] * No copy
[1] All to LCP
[2] All from LCP Copies all parameters in all set-ups from
the LCP memory to the filter memory.
[3] Size indep.
from LCP
Copy only the parameters that are
independent of the active filter size. The
latter selection can be used to programme
several filters with the same function
without disturbing size-dependent data.
0-51 Set-up Copy
Option: Function:
[0] * No copy No function
[1] Copy to set-
up 1
Copies all parameters in the present
programming set-up (defined in
0-11 Programming Set-up) to set-up 1.
[2] Copy to set-
up 2
Copies all parameters in the present
programming set-up (defined in
0-11 Programming Set-up) to set-up 2.
[3] Copy to set-
up 3
Copies all parameters in the present
programming set-up (defined in
0-11 Programming Set-up) to set-up 3.
[4] Copy to set-
up 4
Copies all parameters in the present
programming set-up (defined in
0-11 Programming Set-up) to set-up 4.
[9] Copy to all Copies the parameters in the present set-up
to each of the set-ups 1 to 4.
6.4.6 0-6* Password
0-60 Main Menu Password
Range: Function:
100* [-9999 -
9999 ]
Define the password for access to the Main
Menu via the [Main Menu] key. If
0-61 Access to Main Menu w/o Password is
set to [0] Full access, this parameter is
ignored.
0-61 Access to Main Menu w/o Password
Option: Function:
[0] * Full access
Disables password defined in
parameter 0-60 Main Menu Password.
[1] LCP: Read
only
Prevent unauthorised editing of Main Menu
parameters.
[2] LCP: No
access
Prevent unauthorised viewing and editing of
Main Menu parameters.
[3] Bus: Read
only
Read-only functions for parameters on
Fieldbus and/or FC standard bus.
[4] Bus: No
access
No access to parameters is allowed via
Fieldbus and/or FC standard bus.
[5] All: Read only Read-only function for parameters on LCP,
Fieldbus or FC standard bus.
[6] All: No access No access from LCP, Fieldbus or FC standard
bus is allowed.
If [0] Full access is selected, parameter 0-60 Main Menu
Password, 0-65 Personal Menu Password and 0-66 Access to
Personal Menu w/o Password are ignored.
NOTICE
A more complex password protection is available for
OEMs upon request.
0-65 Quick Menu Password
Range: Function:
200* [-9999 -
9999]
Define the password for access to the Quick
Menu via the [Quick Menu] key. If
parameter 0-66 Access to Quick Menu w/o
Password is set to [0] Full access, this
parameter is ignored.
0-66 Access to Quick Menu w/o Password
If 0-61 Access to Main Menu w/o Password is set to [0] Full access
then this parameter is ignored.
Option: Function:
[0] * Full access
Disables the password defined in
parameter 0-65 Quick Menu Password.
[1] LCP: Read only Prevents unauthorised editing of Quick
Menu parameters.
[3] Bus: Read only Read only functions for Quick Menu
parameters on Fieldbus and/or FC standard
bus.
[5] All: Read only Read only function for Quick Menu
parameters on LCP, Fieldbus or FC standard
bus.
Applications and Basic Prog... Operating Instructions
MG90V302 Danfoss A/S © 09/2014 All rights reserved. 45
6 6

Table of Contents

Other manuals for Danfoss VLT AAF006

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AAF006 and is the answer not in the manual?

Danfoss VLT AAF006 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AAF006
CategoryWater Filtration Systems
LanguageEnglish