15-31 Alarm Log: Value
Array [10]
Range: Function:
0* [-32767 - 32767 ] View an extra description of the error.
This parameter is mostly used in
combination with alarm 38 internal fault.
15-32 Alarm Log: Time
Array [10]
Range: Function:
0 s* [0 - 2147483647 s] View the time when the logged event
occurred. Time is measured in seconds
from unit start-up.
6.8.5 15-4* Unit Identification
Parameters containing read-only information about the
hardware and software configuration of the active filter.
15-40 FC Type
Range: Function:
0* [0 - 6] View the active filter type. The readout is identical
to the type code, characters 1–6.
15-41 Power Section
Range: Function:
0* [0 - 20] View the active filter type. The readout is identical
to the type code, characters 7–10.
15-42 Voltage
Range: Function:
0* [0 - 20] View the active filter type. The readout is identical
to the type code, characters 11–12.
15-43 Software Version
Range: Function:
0* [0 - 5 ] View the combined SW version (or ‘package
version’) consisting of power SW and control SW.
15-44 Ordered Typecode String
Range: Function:
0* [0 - 40 ] View the typecode string used for re-ordering the
active filter in its original configuration.
15-45 Actual Typecode String
Range: Function:
0* [0 - 40 ] View the actual type code string.
15-46 Unit Ordering No
Range: Function:
0 N/A* [0 - 0 N/A] View the 8-digit ordering number used for
re-ordering the active filter in its original
configuration.
15-47 Power Card Ordering No
Range: Function:
0* [0 - 8 ] View the power card ordering number.
15-48 LCP Id No
Range: Function:
0* [0 - 20 ] View the LCP ID number.
15-49 SW ID Control Card
Range: Function:
0* [0 - 20 ] View the control card software version number.
15-50 SW ID Power Card
Range: Function:
0* [0 - 20 ] View the power card software version number.
15-51 Unit Serial Number
Range: Function:
0 N/A* [0 - 0 N/A] View the active filter serial number.
15-53 Power Card Serial Number
Range: Function:
0* [0 - 19 ] View the power card serial number.
6.8.6 15-6* Option Ident.
This read-only parameter group contains information about
the hardware and software configuration of the options
installed in slots A, B, C0 and C1.
15-60 Option Mounted
Array [8]
Range: Function:
0* [0 - 30 ] View the installed option type.
15-61 Option SW Version
Array [8]
Range: Function:
0* [0 - 20 ] View the installed option software version.
15-62 Option Ordering No
Array [8]
Range: Function:
0* [0 - 8 ] Shows the ordering number for the installed
options.
15-63 Option Serial No
Array [8]
Range: Function:
0* [0 - 18 ] View the installed option serial number.
Applications and Basic Prog... Operating Instructions
54 Danfoss A/S © 09/2014 All rights reserved. MG90V302