Navigation Keys
[Back]
for stepping backwards
Arrow [
] [
]
keys are used for manoeuvring between parameter groups, parameters
and within parameters
[OK]
is used for choosing a parameter marked by the cursor and for enabling
the change of a parameter.
130BP079.10
Illustration 7.4: Display example
Operation Keys
Keys for local control are found at the bottom of the control panel.
130BP046.10
Illustration 7.5: Operation keys of the numerical LCP (NLCP)
[Hand on]
enables control of the frequency converter via the LCP. [Hand on] also starts the motor and it is now possible to enter the motor speed data by means
of the arrow keys. The key can be
Enabled
[1] or
Disabled
[0] via par. 0-40 [Hand
on] Key on LCP
.
External stop signals activated by means of control signals or a serial bus will override a 'start' command via the LCP.
The following control signals will still be active when [Hand on] is activated:
[Hand on] - [Off] - [Auto on]
Reset
Coasting stop inverse
•Reversing
Set-up select lsb - Set-up select msb
Stop command from serial communication
•Quick stop
•DC brake
[Off]
stops the connected motor. The key can be
Enabled
[1] or
Disabled
[0] via par. 0-41 [Off]
Key on LCP
.
If no external stop function is selected and the [Off] key is inactive the motor can be stopped by disconnecting the mains supply.
[Auto on]
enables the frequency converter to be controlled via the control terminals and/or serial communication. When a start signal is applied on the control
terminals and/or the bus, the frequency converter will start. The key can be
Enabled
[1] or
Disabled
[0] via par. 0-42 [Auto
on] Key on LCP
.
NB!
An active HAND-OFF-AUTO signal via the digital inputs has higher priority than the control keys [Hand on] [Auto on].
[Reset]
is used for resetting the frequency converter after an alarm (trip). The key can be
Enabled
[1] or
Disabled
[0] via par. 0-43 [Reset]
Key on LCP
.
7.1.4. Changing Data
1. Press [Quick Menu] or [Main Menu] key.
VLT
®
AQUA Drive
Operating Instructions
7. How to operate the frequency converter
MG.20.M5.02 - VLT
®
is a registered Danfoss trademark
57
7

Table of Contents

Other manuals for Danfoss VLT AQUA Drive FC 202