[3] In range See parameter group 5-3* for further description.
[4] On reference See parameter group 5-3* for further description.
[5] Torque limit See parameter group 5-3* for further description.
[6] Current limit See parameter group 5-3* for further description.
[7] Out of current range See parameter group 5-3* for further description.
[8] Below I
LOW
See parameter group 5-3* for further description.
[9] Above I
HIGH
See parameter group 5-3* for further description.
[10] Out of speed range
[11] Below speed low See parameter group 5-3* for further description.
[12] Above speed high See parameter group 5-3* for further description.
[13] Out of feedb. range
[14] Below feedb. low
[15] Above feedb. high
[16] Thermal warning See parameter group 5-3* for further description.
[17] Mains out of range See parameter group 5-3* for further description.
[18] Reversing See parameter group 5-3* for further description.
[19] Warning See parameter group 5-3* for further description.
[20] Alarm (trip) See parameter group 5-3* for further description.
[21] Alarm (trip lock) See parameter group 5-3* for further description.
[22] Comparator 0 Use the result of comparator 0 in the logic rule.
[23] Comparator 1 Use the result of comparator 1 in the logic rule.
[24] Comparator 2 Use the result of comparator 2 in the logic rule.
[25] Comparator 3 Use the result of comparator 3 in the logic rule.
[26] Logic rule 0 Use the result of logic rule 0 in the logic rule.
[27] Logic rule 1 Use the result of logic rule 1 in the logic rule.
[28] Logic rule 2 Use the result of logic rule 2 in the logic rule.
[29] Logic rule 3 Use the result of logic rule 3 in the logic rule.
[33] Digital input DI18 Use the value of DI18 in the logic rule (High = TRUE).
[34] Digital input DI19 Use the value of DI19 in the logic rule (High = TRUE).
[35] Digital input DI27 Use the value of DI27 in the logic rule (High = TRUE).
[36] Digital input DI29 Use the value of DI29 in the logic rule (High = TRUE).
[37] Digital input DI32 Use the value of DI32 in the logic rule (High = TRUE).
[38] Digital input DI33 Use the value of DI33 in the logic rule (High = TRUE).
[39] Start command This event is TRUE if the frequency converter is started by any
means (either via digital input, field bus or other).
VLT
®
AQUA Drive Programming Guide 2. Parameter Description
MG.20.O2.02 - VLT
®
is a registered Danfoss trademark
133
2

Other manuals for Danfoss vlt aqua

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss vlt aqua and is the answer not in the manual?

Danfoss vlt aqua Specifications

General IconGeneral
Supply Voltage200-240V, 380-500V, 525-600V
EnclosureIP20
FeaturesEnergy optimization
ApprovalsCE, UL, cUL
Input Voltage Range200-240V, 380-500V, 525-600V
Output Voltage Range0 to supply voltage
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short circuit, Ground fault
Communication InterfacesPROFIBUS
Cooling MethodAir-cooled