[38] Display Text 2 Enables an individual text string to be written, for display in the
LCP or to be read via serial communication.
[39] Display Text 3 Enables an individual text string to be written, for display in the
LCP or to be read via serial communication.
[89] Date and Time Read-
out
Displays the current date and time.
[953] Profibus Warning
Word
Displays Profibus communication warnings.
[1005] Readout Transmit Er-
ror Counter
View the number of CAN control transmission errors since the
last power-up.
[1006] Readout Receive Er-
ror Counter
View the number of CAN control receipt errors since the last
power-up.
[1007] Readout Bus Off
Counter
View the number of Bus Off events since the last power-up.
[1013] Warning Parameter View a DeviceNet-specific warning word. One separate bit is as-
signed to every warning.
[1115] LON Warning Word Shows the LON-specific warnings.
[1117] XIF Revision Shows the version of the external interface file of the Neuron C
chip on the LON option.
[1118] LON Works Revision Shows the software version of the application program of the
Neuron C chip on the LON option.
[1501] Running Hours View the number of running hours of the motor.
[1502] kWh Counter View the mains power consumption in kWh.
[1600] Control Word View the Control Word sent from the frequency converter via
the serial communication port in hex code.
[1601]
*
Reference [Unit] Total reference (sum of digital/analog/preset/bus/freeze ref./
catch up and slow-down) in selected unit.
[1602] Reference % Total reference (sum of digital/analog/preset/bus/freeze ref./
catch up and slow-down) in percent.
[1603] Status Word Present status word
[1605] Main Actual Value [%] One or more warnings in a Hex code
[1609] Custom Readout View the user-defined readouts as defined in par. 0-30, 0-31
and 0-32.
[1610] Power [kW] Actual power consumed by the motor in kW.
[1611] Power [hp] Actual power consumed by the motor in HP.
[1612] Motor Voltage Voltage supplied to the motor.
[1613] Motor Frequency Motor frequency, i.e. the output frequency from the frequency
converter in Hz.
[1614] Motor Current Phase current of the motor measured as effective value.
[1615] Frequency [%] Motor frequency, i.e. the output frequency from the frequency
converter in percent.
VLT
®
AQUA Drive Programming Guide 2. Parameter Description
MG.20.O2.02 - VLT
®
is a registered Danfoss trademark
31
2

Other manuals for Danfoss vlt aqua

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss vlt aqua and is the answer not in the manual?

Danfoss vlt aqua Specifications

General IconGeneral
Supply Voltage200-240V, 380-500V, 525-600V
EnclosureIP20
FeaturesEnergy optimization
ApprovalsCE, UL, cUL
Input Voltage Range200-240V, 380-500V, 525-600V
Output Voltage Range0 to supply voltage
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short circuit, Ground fault
Communication InterfacesPROFIBUS
Cooling MethodAir-cooled