Option
Name
Description
[30]
Set vir. mas. pos.
to actual
N O T I C E
This option is only available with software version 48.XX.
Bit for setting the virtual master position = the actual follower position. This is needed for setting
the correct starting position for position-controlled virtual master ensuring that the virtual master
ensuring that the virtual master position is aligned with the physical position of the follower.
[31]
Activate CAM ta-
ble
N O T I C E
This option is only available with software version 48.XX.
Signal for activating a new CAM table while running with bumpless transfer.
[32]
Halt
[33]
Bit 10 = 0 > CTW
TO always
[78]
Reset preventive
maintenance
word
[94]
Light load detec-
tion
Use this option to ensure drive runs in the direction which requires least energy (UPS capacity),
during an emergency.
[95]
Evacuation mode
Use this function to operate the drive at reduced DC voltage for evacuating people in case of pow-
er failure.
[189]
Emergency mode
[190]
Emcy mode ref bit
0
Enables a choice between 1 of the 8 preset references.
[191]
Emcy mode ref bit
1
Enables a choice between 1 of the 8 preset references.
[192]
Emcy mode ref bit
2
Enables a choice between 1 of the 8 preset references.
[195]
Test emcy mode
Emergency mode is activated in a special test mode where the drive stops on all alarms.
[231]
Power limit mot.
N O T I C E
This option is only available in FC 302.
See parameter group 4-8* Power Limit. Use this option in the motor mode only.
[232]
Power limit gen.
N O T I C E
This option is only available in FC 302.
See parameter group 4-8* Power Limit. Use this option in the generating mode only.
AU275636650261en-000101 / 130R0334282 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 300 Series and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 300 Series Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 300 Series
CategoryDC Drives
LanguageEnglish

Related product manuals