Parameter 34-41 Digital Outputs
Table 1260: Parameter 34-41 Digital Outputs
34-41 Digital Outputs
Default value: 0
Parameter type: Range, 0 - 255
Setup: All setups
Conversion index: 0
Data type: Uint16
Change during operation: True
5.27.4 34-5* Process Data
Parameter 34-50 Actual Position
Table 1261: Parameter 34-50 Actual Position
34-50 Actual Position
Default value: 0
Parameter type: Range, -1073741824 - 1073741823
Setup: All setups
Conversion index: 0
Data type: Int32
Change during operation: True
The actual position in user unit.
Parameter 34-51 Commanded Position
Table 1262: Parameter 34-51 Commanded Position
34-51 Commanded Position
Default value: 0
Parameter type: Range, -1073741824 - 1073741823
Setup: All setups
Conversion index: 0
Data type: Int32
Change during operation: True
Parameter 34-52 Actual Master Position
Table 1263: Parameter 34-52 Actual Master Position
34-52 Actual Master Position
Default value: 0
Parameter type: Range, -1073741824 - 1073741823
Setup: All setups
Conversion index: 0
Data type: Int32
Change during operation: True
Parameter 34-53 Slave Index Position
Table 1264: Parameter 34-53 Slave Index Position
34-53 Slave Index Position
Default value: 0
Parameter type: Range, -1073741824 - 1073741823
Setup: All setups
Conversion index: 0
Data type: Int32
Change during operation: True
Parameter 34-54 Master Index Position
Table 1265: Parameter 34-54 Master Index Position
34-54 Master Index Position
Default value: 0
Parameter type: Range, -1073741824 - 1073741823
Setup: All setups
Conversion index: 0
Data type: Int32
Change during operation: True
Parameter 34-55 Curve Position
Table 1266: Parameter 34-55 Curve Position
34-55 Curve Position
Default value: 0
Parameter type: Range, -1073741824 - 1073741823
Setup: All setups
Conversion index: 0
Data type: Int32
Change during operation: True
AU275636650261en-000101 / 130R0334628 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 300 Series and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 300 Series Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 300 Series
CategoryDC Drives
LanguageEnglish

Related product manuals