EasyManuals Logo
Home>Danfoss>DC Drives>VLT AutomationDrive FC 300 Series

Danfoss VLT AutomationDrive FC 300 Series Programming Guide

Danfoss VLT AutomationDrive FC 300 Series
722 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #578 background imageLoading...
Page #578 background image
Parameter 30-05 Wobble Jump Frequency [%]
Table 1068: Parameter 30-05 Wobble Jump Frequency [%]
30-05 Wobble Jump Frequency [%]
Default value: 0%
Parameter type: Range, 0 - 100 %
Setup: All setups
Conversion index: 0
Data type: Uint8
Change during operation: True
The jump frequency can also be expressed as a percentage of the center frequency. The function is the same as for parameter 30-04
Wobble Jump Frequency [Hz].
Parameter 30-06 Wobble Jump Time
Table 1069: Parameter 30-06 Wobble Jump Time
30-06 Wobble Jump Time
Default value: Size related
Parameter type: Range, 0.005 - 5.000 s
Setup: All setups
Conversion index: -3
Data type: Uint16
Change during operation: True
This parameter determines the slope of the jump ramp at the maximum and minimum wobble frequency.
Parameter 30-07 Wobble Sequence Time
Table 1070: Parameter 30-07 Wobble Sequence Time
30-07 Wobble Sequence Time
Default value: 10 s
Parameter type: Range, 1 - 1000 s
Setup: All setups
Conversion index: -1
Data type: Uint16
Change during operation: True
This parameter determines the wobble sequence period. This parameter can only be changed in stop mode.
Wobbletime = tup + tdown
Parameter 30-08 Wobble Up/Down Time
Table 1071: Parameter 30-08 Wobble Up/Down Time
30-08 Wobble Up/Down Time
Default value: 5 s
Parameter type: Range, 0.1 - 1000 s, Array [2]
Setup: All setups
Conversion index: -1
Data type: Uint16
Change during operation: True
Defines the individual up and down times for each wobble cycle.
Parameter 30-09 Wobble Random Function
Table 1072: Parameter 30-09 Wobble Random Function
30-09 Wobble Random Function
Default value: [0] Off
Parameter type: Option
Setup: All setups
Conversion index: -
Data type: Uint8
Change during operation: True
Option
Name
Description
[0]*
Off
[1]
On
AU275636650261en-000101 / 130R0334578 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 300 Series and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 300 Series Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 300 Series
CategoryDC Drives
LanguageEnglish

Related product manuals