Handbuch Datafox EVO 3.5 Pure Seite 51 Datum: 06.08.2018 Version: 04.03.07.XX
Service-connection (active-mode)
The content of the SMS is similar to that of HTTP-Answer from the WEB-Server.
Actually supported are 3 keywords: service, host and port. The keyword must follow
an “=” character with corresponding value. The individual fields are separate with the character &.
With the KEY „service=1, open the device a Service-connection. The connection Parameters
(Host, Port) are saved in the “active.ini” file from the device.
An option is, to give the device the Parameters for the connection via SMS (->host=, port=). Then
use the device this parameters from the SMS and not the saved from the “active.ini” (active mode).
&service=2
Coution ! this funktion first supportet with the hardware version V4 GPRS(Mobilfunk) and FW 04.03.06.XX.
When using parameter 2, the service connection is established immediately.
Beispiele:
a) service=X&key=12345
b) service=X&host=www.datafox.de&key=12345
c) service=X&host=123.123.123.123&key=12345
d) service=X&host=www.datafox.de&port=4711&key=12345
a) Connection to the server with the saved parameters in the „active mode“.
b) and c) Connection on Port 8000 to the server (www.datafox.de/123.123.123.123).
d) Connection to the server www.datafox.de and port 4711.