Handbuch Datafox EVO 3.5 Pure Seite 80 Datum: 06.08.2018 Version: 04.03.07.XX
A Door with a Separate Reader
The EVO 3.5 Pure is installed in a protected area inside a building and the reader is installed out-
side. The terminal is access master and door-opener at the same time. The door opening relay is in
the PZEMasterIV and thus installed in the protected area. The access identification captured by the
reader is transferred to the EVO 3.5 Pure and analyzed by it. If access is permitted, the door is
opened via the relay in the .
Installation plan:
This version is used frequently and can be installed easily and economically as shown in the figure
above.
Wiring plan:
:
Reader table for this example
ID
ZM
TM
RefLocation
RefAction
PinGeneral
Description
1
1
320
0
1
0
Access master
2
1
010
1
1
0
Reader on RS485 (L)
RS232/485
TCP/IP usw.
RS485 connection max. 1000 m
Relay to the door
Dorr monitoring
Reader (L)
Art-Nr.:106020
Power: max 30 V 2A
door opener
Reader module (L)
Art-Nr.:106020